Highlights:
①19 samples can be loaded once + 1 blank sample position for analyzing the moisture, ash and volatile matter.
②Unique sample weighing mode, single sample or batch sample weighing are both available, makes the operation convenient.
③Automatic temperature calibration function is available.
④Flexible software design, test procedure, analysis time, temperature etc. can be customized.
⑤LED displays on furnaces to show real-time balance weight data, it makes the sample weighing more convenient.
⑥Single and dual furnace configurations available.
Specification:
| Description | SDTGA6000A | 
| Test index | Moisture, ash ,volatile matter and LOI | 
| Continuous test in batches | Yes | 
| Standards | ISO 17246, ISO 18123/18122/18134, ISO 11722, ISO 1171,ASTM D3173/D3174/D3175/D7582, GB/T 30732, GB/T 212 | 
| Precision | 0.02% RSD | 
| Furnace temperature | Room temperature~1000℃ | 
| Temperature control precision | ±2℃ | 
| Temperature resolution | 0.1℃ | 
| Reproducibility | Ash: 0.30% (<15.00%); 0.50% (15.00~30.00%); 0.70% (>30.00%)Volatile matter: 0.50% (<20.00%); 1.00% (20.00~40.00%); 1.50% (>40.00%) | 
| Cooling time required for batches of test | No | 
| Furnace Cooling (forced air/N2) | 950 to 500°C<30 min | 
| Balance Resolution | 0.0001g | 
| Sample introduction and taking | Automatic | 
| Max. Samples | 19 samples + 1 blank sample position | 
| Quantity of sample / test time: | Full indexes for 19 samples< 120 min (Quick method) | 
| Sample weight | 0.5 up to 5g | 
| Max. power | 4kW | 
| Interface: | RS232 | 
| Furnace Heating | Resistance Wound | 
| Temperature Calibration | Standard thermocouple | 
| Temp. control precision | ±2℃ (moisture) ±5℃ (ash, volatile matter) | 
| Gas Flow Rate | GB:Moisture:Nitrogen,30~60 times/h Ash:Air 60~120 times/h ASTM:Moisture:Nitrogen or Air 2~4(Furnace Volume /min)volatile matter:Nitrogen 2~4(Furnace Volume /min) | 
| Power requirement | AC 220 V(±10%),50 / 60Hz | 
| Gas requirement | Nitrogen/Oxygen/Compressed Air | 
| Gas Pressure | Air 5 to 6 bar (75 to 90 psi) | 
| Minimum Gas Purity | Air/Nitrogen/Oxygen 99.5%; dry, oil-free | 
| Sample weighing | Under normal temp. | 
| Test Temperature | Moisture 105℃,Ash 815℃,Volatile matter 920℃~950℃ Can be customized | 
| Humidity | <80% | 
| Dimensions | 550*590*530mm | 
| Weight | 70kg | 
| Operational Control | Windows®-based software on external PC/Windows7/ WindowsXP | 
| Advance Calculation | Yes | 
| Analysis Report | Yes | 
| Statistics Report | Yes | 
| System Monitor | Yes | 
      0086-731-88112150   sales@sandegroup.com
     0086-731-88112150   sales@sandegroup.com 



 
         
         
  
                        

 
 



 0086 731 88112150
 0086 731 88112150 0086 731 88134650
 0086 731 88134650 sales@sandegroup.com
 
	sales@sandegroup.com